Rexroth IndraDrive
Command Diagnostic Messages
9-81
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
C0852 Locked with password
Supported by Supply Unit:
HMV01
Note:
This command error can only occur as a result of the
C0800
Load basic parameters command
that can only be used by
the manufacturer!
C0852 - Attributes
Display:
C0852
Mess. no.:
C0852 (hex)
C0902 Spindle positioning requires drive enable
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
FWA-INDRV*-
MPB02
VRS-MS
During the execution of the command for spindle positioning (C0900) an
error was detected.
Cause:
At the start of the
S-0-0152, C0900 Position spindle command
the drive
was not yet in drive enable.
Remedy:
Set drive enable before starting the command.
C0902 - Attributes
Display:
C0902
Mess. no.:
C0902 (hex)