7-20
Error Messages
Rexroth IndraDrive
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
F8102 Error when initializing power section
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
FWA-INDRV*-
MPB02
VRS-MS
FWA-INDRV*-
MPD02
VRS-MS
During the initialization of the drive the power section is checked for
correct function. An error was detected during this check.
Cause
Remedy
Hardware and firmware do not match
Check Firmware Release Notes or Firmware Version
Notes and, if necessary, use latest firmware release
Parameter
P-0-1510, Circuit board code power
section
stored on power section is invalid or was
incorrectly written
Switch drive off and on again. If error occurs again,
check content of
P-0-1510, Circuit board code power
section
and contact our service department!
Maybe you have to replace power section or entire drive
controller
Hardware defect on power section
Replace power section or entire drive controller
Note:
Only Rexroth service engineers or especially trained users are
allowed to replace the control section. The replacement of the
entire drive controller is described in the Project Planning
Manual for the power section.
F8102 - Attributes
Display:
F8102
Mess. no.:
F8102 (hex)
F8118 Invalid power section/firmware combination
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
FWA-INDRV*-
MPB02
VRS-MS
FWA-INDRV*-
MPD02
VRS-MS
The power section is incompatible with the firmware used.
Cause
Remedy
Inappropriate firmware
Use firmware that matches power section
Inappropriate power section
Use power section that matches firmware
F8118 - Attributes
Display:
F8118
Mess. no.:
F8118 (hex)