Rexroth IndraDrive
Error Messages
7-71
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
F3146 System error channel 2
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
FWA-INDRV*-
MPB02
VRS-MS
FWA-INDRV*-
MPD02
VRS-MS
The drive is shut down according to the setting in
P-0-0119, Best
possible deceleration
.
The drive automatically switches to safety related standstill and the output
stage is switched off via two channels.
As soon as the axis has stopped the safety door can be opened.
Cause
Remedy
System error on channel 2
Reset module by switching control voltage on and off.
Start command
S-0-0099, C0500 Reset class 1
diagnostics
in order to clear error an then set drive
enable again.
If error occurs repeatedly, replace control section or
entire drive controller
Note:
Only Rexroth service engineers or especially trained users are
allowed to replace the control section. The replacement of the
entire drive controller is described in the Project Planning
Manual for the power section.
F3146 - Attributes
Display:
F3146
Mess. no.:
F3146 (hex)
LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01