Rexroth IndraDrive
Command Diagnostic Messages
9-3
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
C0500 Reset class 1 diagnostics, error reset
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
FWA-INDRV*-
MPB02
VRS-MS
FWA-INDRV*-
MPD02
VRS-MS
Supported by Supply Unit:
HMV01
The command for clearing errors,
S-0-0099, C0500 Reset class 1
diagnostics
, was activated. All drive-internal errors are cleared.
Note:
Only those errors can be cleared that were removed! Errors
that are still present after clearing will cause the error
message to be generated again.
C0500 - Attributes
Display:
C05
Mess. no.:
C0500 (hex)
C0600 Drive-controlled homing procedure command
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
FWA-INDRV*-
MPB02
VRS-MS
FWA-INDRV*-
MPD02
VRS-MS
The command for drive-controlled homing,
S-0-0148, C0600 Drive-
controlled homing procedure command
, was activated.
See also Functional Description "Drive-Controlled Homing"
C0600 - Attributes
Display:
C06
Mess. no.:
C0600 (hex)