4-4
Diagnostic Messages when Booting the Devices
Rexroth IndraDrive
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Firmware update ?
Brief Description:
Different firmware in device and on MMC
During the booting process with the MMC plugged in, a check is run by
means of the release version to find out whether the firmware (FW) on
the flash is identical to the one on the MMC.
Cause
Remedy
Check showed that firmware on flash and on MMC
are not identical
Switch drive off and install MMC in drive with the same
release version as on flash
–
or
–
Confirm diagnostic message with "ENTER" and start
firmware update
Update Error !
Brief Description:
Firmware update error during booting process
Cause
Remedy
Firmware update was not carried out correctly
Reboot device and start firmware update
–
or
–
Switch drive off, remove MMC and carry out firmware
update on PC via auxiliary program "Dolfi"
LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01