6-16
Status Diagnostic Messages
Rexroth IndraDrive
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
A0108 Drive controlled interpolation, lagless, encoder 1
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
FWA-INDRV*-
MPB02
VRS-MS
FWA-INDRV*-
MPD02
VRS-MS
From the master the drive receives a position command value identical to
the target position of the distance to be traveled. The drive then generates
(interpolates) an internal position command value characteristic that
complies with the maximum values for the jerk, acceleration and velocity
characteristic determined by the master.
The drive laglessly moves to the target position (prerequisite:
P-0-0040,
Velocity feedforward evaluation
=100%).
"Encoder 1" means that the encoder assigned by means of
P-0-0077,
Assignment motor encoder->optional slot
is used as a control
encoder.
See also Functional Description "Drive Internal Interpolation"
A0108 - Attributes
Display:
AF
Mess. no.:
A0108 (hex)
A0109 Drive controlled interpolation, lagless, encoder 2
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
FWA-INDRV*-
MPB02
VRS-MS
FWA-INDRV*-
MPD02
VRS-MS
From the master the drive receives a position command value identical to
the target position of the distance to be traveled. The drive then generates
(interpolates) an internal position command value characteristic that
complies with the maximum values for the jerk, acceleration and velocity
characteristic determined by the master.
The drive laglessly moves to the target position (prerequisite:
P-0-0040,
Velocity feedforward evaluation
=100%).
"Encoder 2" means that the encoder assigned by means of
P-0-0078,
Assignment optional encoder->optional slot
is used as a control
encoder.
See also Functional Description "Drive Internal Interpolation"
A0109 - Attributes
Display:
AF
Mess. no.:
A0109 (hex)
LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01