Status Diagnostic Messages
6-37
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
A4000 Automatic drive check and adjustment
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
FWA-INDRV*-
MPB02
VRS-MS
FWA-INDRV*-
MPD02
VRS-MS
The A4000 diagnostic message is a collective diagnostic message for
different system states. It is used for drive check and adjustment. When
enabling and disabling the drive enable this diagnosis is automatically
activated. The following system states that are processed independent of
the parameterization are counted among the drive checks and
adjustments:
•
the holding brake delay times (
S-0-0206, Drive on delay time
,
S-0-0207, Drive off delay time
)
•
build-up of the air-gap field (in the case of asynchronous motors)
•
automatic determination of the commutation offset (in the case of
synchronous motors with incremental measuring system)
Depending on the parameterization the automatic brake check is
displayed with the A4000 diagnostic message, too (see
P-0-0525,
Holding brake control word
).
A4000 - Attributes
Display:
AC
Mess. no.:
A4000 (hex)
A4001 Drive deceleration to standstill
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
FWA-INDRV*-
MPB02
VRS-MS
FWA-INDRV*-
MPD02
VRS-MS
The drive
•
is decelerated to standstill as set in the
P-0-0119, Best possible
deceleration
parameter
- or -
•
conducts a speed command value reset.
Note:
This status is displayed on the control panel of the drive with
"AE".
See also Functional Description "Error"
A4001 - Attributes
Display:
AE
Mess. no.:
A4001 (hex)