Rexroth IndraDyn A
Motors for Hazardous Areas
13-15
DOK-MOTOR*-MAD/MAF****-PR03-EN-P
or air duct length, as well as the air baffles, into account. Please also
observe the notes in Chapter 9.8 ”Motor Cooling”.
1
2
3
Ex-Belueftung.EPS
(1):
Explosion-endangered area
(2):
Radial fan (not included in scope of delivery)
(3):
MAD motor in EX version
Fig. 13-13: Fan connection in the explosion-protected area
Coolant Connection to MAF Motors
Regarding the coolant connection to MAF motors, please heed the
information in chapter 8, Connection Techniques.
Purging Connections
The connection of an EX motor with an EEx p control device has to be
done with a pipe or a tube with a maximum internal diameter of 8 mm.
If plastic pipes are used, the maximum outer diameter is 13 mm.
CAUTION
Possible electrostatic discharge from plastic
pipes!
⇒
Use only plastic pipes that are certified for use in
explosion-protected areas.
Connect the pneumatic purging gas lines by heeding the maximum
permitted bending cycles according to Fig. 13-14.
Summary of Contents for Rexroth IndraDyn A Series
Page 10: ...VIII Table of Contents Rexroth IndraDyn A DOK MOTOR MAD MAF PR03 EN P ...
Page 14: ...1 4 Introduction to the Product Rexroth IndraDyn A DOK MOTOR MAD MAF PR03 EN P ...
Page 150: ...5 42 Dimension Sheets IndraDyn A Rexroth IndraDyn A DOK MOTOR MAD MAF PR03 EN P ...
Page 174: ...6 24 Type Codes IndraDyn A Rexroth IndraDyn A DOK MOTOR MAD MAF PR03 EN P ...
Page 196: ...8 16 Connection Techniques Rexroth IndraDyn A DOK MOTOR MAD MAF PR03 EN P ...
Page 238: ...9 42 Application Notes Rexroth IndraDyn A DOK MOTOR MAD MAF PR03 EN P ...
Page 256: ...12 10 Operating IndraDyn A Motors Rexroth IndraDyn A DOK MOTOR MAD MAF PR03 EN P ...
Page 285: ...Rexroth IndraDyn A Index 14 5 DOK MOTOR MAD MAF PR03 EN P ...
Page 286: ...14 6 Index Rexroth IndraDyn A DOK MOTOR MAD MAF PR03 EN P ...
Page 287: ......