Rexroth IndraDyn A
Technical Data
4-13
DOK-MOTOR*-MAD/MAF****-PR03-EN-P
4.5
Data Sheet MAD100D
Description
Symbol
Unit
MAD100D
Motor data
1
)
Winding
0050
0100
0150
0200
0250
Rated torque
M
N
Nm
70
64
59
54
50
Rated power
P
N
kW
3.7
6.7
9.3
11.3
13.1
Rated current
I
N
A
10.1
19.3
25.6
27.2
32.4
Rated speed
n
N
rpm
500
1000
1500
2000
2500
Key speed
n
1
rpm
500
500
1000
1500
2000
Maximum torque
M
max
Nm
154
146
141
130
119
Maximum output
P
max
kW
7.6
13.7
19.1
23.2
26.9
Maximum current
I
max
A
19.1
34.3
47.6
52.7
64
N
n
max
rpm
3000
6000
9000
R
n
max
rpm
3000
6000
6300
V
n
max
rpm
not available
Maximum speed
with bearing…
H
n
max
rpm
3000
6000
9000
11000
7
)
Continuous torque at standstill
M
n1
Nm
70
70
64
59
54
Continuous current at standstill
I
n1
A
10.1
20.4
26.8
28.7
34.7
Torque constant at 20° C
K
M_N
Nm/A
8.52
4.5
3.19
2.62
2.04
Thermal time constant
T
th
min
30
Duty cycle time (S6-44%)
T
C
min
10
Discharge capacity
C
ab
nF
11
11
10.2
11.5
11.9
Number of pole pairs
p
3
Power wire cross-section
2
)
A
mm²
1
2.5
4
4
6
Moment of inertia
3
)
J
rot
kgm²
0.0392
Mass
4
)
m
kg
72
Sound pressure level
5
)
L
P
dB(A)
70 (+3)
Ambient temperature in operation
T
um
°C
0....+40
Insulation class according to DIN
EN 60034-1
F
Motor protection class
IP65
Holding brake (optional)
Electrically clamping
Electrically releasing
Transmittable torque
M
4
Nm
30
24
Connection voltage
U
Br
V
DC 24 ± 10 %
Rated current
I
Br
A
0.9
1.1
Moment of inertia
J
Br
kgm²
0.00056
Max. permissible braking energy
W
max
Ws
20000
Disconnection time
t
2
ms
50
90
Connection time
t
1
ms
42
30
Maximum speed brake
n
Br_max
rpm
10000
10000
Mass
m
kg
2
1.6
Fan
Axial fan
Air current
B
→
A, blowing
Connection voltage
U
N
V
3 x 400V ±15 %, 50/60Hz ..... 3 x 480V ±10 %, 50/60 Hz
Power consumption
S
N
VA
83 .... 100
Fan flow
6
)
I
N
A
0.12
Medium air voltage
V
m³/h
230
1
)
Values determined according to IEC 60034-1. Current and voltage specified as root-mean-square values.
Reference value = 540 V
DC
intermediate circuit.
2
)
Please note the explanations on power wire cross section in Chapter 4.2, Operating Behavior.
3
)
Value without holding brake.
4
)
Value without holding brake, with fan.
5
)
At 1m distance, with PWM = 4 kHz
6
)
With I
N
+ 20% and higher, fans should be monitored.
7
)
Value without holding brake. Observe maximum speed of holding brake.
Fig. 4-17:
Data sheet MAD100D
Summary of Contents for Rexroth IndraDyn A Series
Page 10: ...VIII Table of Contents Rexroth IndraDyn A DOK MOTOR MAD MAF PR03 EN P ...
Page 14: ...1 4 Introduction to the Product Rexroth IndraDyn A DOK MOTOR MAD MAF PR03 EN P ...
Page 150: ...5 42 Dimension Sheets IndraDyn A Rexroth IndraDyn A DOK MOTOR MAD MAF PR03 EN P ...
Page 174: ...6 24 Type Codes IndraDyn A Rexroth IndraDyn A DOK MOTOR MAD MAF PR03 EN P ...
Page 196: ...8 16 Connection Techniques Rexroth IndraDyn A DOK MOTOR MAD MAF PR03 EN P ...
Page 238: ...9 42 Application Notes Rexroth IndraDyn A DOK MOTOR MAD MAF PR03 EN P ...
Page 256: ...12 10 Operating IndraDyn A Motors Rexroth IndraDyn A DOK MOTOR MAD MAF PR03 EN P ...
Page 285: ...Rexroth IndraDyn A Index 14 5 DOK MOTOR MAD MAF PR03 EN P ...
Page 286: ...14 6 Index Rexroth IndraDyn A DOK MOTOR MAD MAF PR03 EN P ...
Page 287: ......