42/60
Bosch Rexroth AG
|
Electric Drives and Controls
LTH | 3 609 929 408/2.1
2 Power Unit LTH
2.6.1
Connecting an EC power tool and an external control (e.g. SE 200)
The cable set from the manufacturer must be used to connect an external control to power unit LTH. The
units are connected according to fig. 5.
The control is connected via the IEC receptacle of the power unit to the power line.
WARNING:
The safety measure “isolation by transformer” is used by power unit LTH. Therefore,
only power tool components and cables intended or authorized by the manufacturer
must be connected (see chapter 3 “Overview of Order Numbers for Smart Tools”).
Fig. 5:
Connecting an EC power tool and an external control
SE 200
LTH
0
X8
X7
X3
X2
X8
X2
X1
X7
X1
Netz
Power supply