LTH | 3 609 929 408/2.1
2 Power Unit LTH
2.9.5.3 Function Chart
Fig. 10: Function Chart
2.9.5.4 Parameter explanation
Count
Add
The counter counts the IO bolting actions upward (additive counting mode). As soon as the preselected
value has been reached, the SIO output is set at the user interface (X13).
Sub
The counter starts with the preselected value and counts down for every IO bolting action until it reaches
0 (subtractive counting mode). As soon as 0 has been reached, the SIO output is set at the user interface
(X13).
Loop
on
In additive counting mode: As soon as the preselected value has been reached, the SIO output is set for
an adjustable period of time at the user interface (X13). Then the counter is set to 0 and counting begins
again.
6
6
1
6
1
6
1
6
1
1
6
5
<5s
=5s
Segment-
Test
Resettaste u.
Tasten der 5. u. 6. Dekade
drücken
Parameter geändert
<1s
1
Schaltet zum
nächsten
Parameter
6
1
Parameterauswahl
6
Press reset key together
with keys of decades 5 and
6
Parameters changed
LCD-test
Step to next
parameter
Change parameter