![background image](http://html.mh-extra.com/html/bosch/rexroth-lu-2/rexroth-lu-2_assembly-instructions-manual_46205015.webp)
Function 15/54
3 842 358 814/2017-01, MIT: LU 2,
Bosch Rexroth AG
6.1.1
Setting the delivery volume in the TIME operating mode
The mode of operation, the oil container used LC 2 (
Ö
LC250) and the delivery
period is entered via the display using the
SET
button.
The delivery period must be entered in relation to the required delivery volume,
interval period and the oil tank used LC 2 (
Ö
LC250) (see Table 5 on page 14).
• The input is executed with the power supply disconnected. The power supply for
the electronics comes from an integrated backup battery.
• The oil container LC 2 must be installed on the drive prior to the setting
(see page 31).
In the as delivered condition the display is on the left.
1.
Press and hold the
SET
button (> 5 s), until the modes
TIME
and
PULSE
fl ash
in the display.
2.
Press
1x
the
SET
button.
The display switches to the
TIME
mode (TIME fl ashes).
After about 3 seconds, the display switches to the selection of the oil container.
3.
Press SET button 1x
¨
LC60
Press SET button 2x
¨
LC120
Press
SET
button
3x
¨
LC250
(= LC 2)
The selected oil container fl ashes in the display (here LC250).
After about 3 seconds, the display switches to the entry of the metered lubricant
delivery period.
4.
To enter the delivery period press the
SET
button repeatedly.
Months
1
...
12
can be scrolled through.
The delivery period entered fl ashes in the display.
Approximately 3 seconds after the entry (inactive SET button) the setting mode
for the delivery period is terminated.
The operating mode, the entered delivery period, the entered oil container LC 2
(
Ö
LC250) and the metered volume to be delivered per 100 hours are shown on
the display.
358 814-27
358 814-28
358 814-29
358 814-30
358 814-31
358 814-32
358 814-33
358 814-34
EN
GLISH
358814_2017_01_EN.indd 15