7. Remove the protective sleeve of the motor drive shaft and keep it for
further use.
8. Only for motors with holding brake:
Check whether the motor holding brake reaches the holding torque
specified in the data sheet. Should the brake fail to reach the torque
specified, first resurface the holding brake as described under Chapter
9.12.5.
12.3.3
Assembly
Please note the following points when mounting the motors:
1. Avoid pinching or jamming the centering collar on the motor side.
2. Avoid damage to the insertion fitting on the system side.
3. Before you proceed, check the fit and precision of the connection.
After having assembled the motor mechanically, prepare it for electrical con‐
nection.
Bosch Rexroth AG
DOK-MOTOR*-MKE*GEN2***-PR06-EN-P
Rexroth MKE Synchronous Motors for Potentially Explosive Areas acc. to ATEX and UL/CSA
108/135
Installation
LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01