When using ready-made encoder cables, remove the fitting, which is moun‐
ted on the motor and use the fitting, which is mounted on the cable.
It is not necessary to define the cable outer diameter, now.
①
Sealing
②
Screwed connection
③
Use grommets according to the cable diameter.
④
Union nut
⑤
Ready-made power cable
⑥
Terminal box lid
⑦
Cover screws
⑧
Ready-made encoder cable
Fig.12-10:
Mounting the EExd-fitting and MKE118 cable
Loosen and re-tighten the cable fittings is not permitted. In this
cases, a "new grommet" is to be used.
1. Connect the shield.
Connect the ring terminal of the power and encoder cabel on the X5
within the terminal box lid
(Tightening torque 1.3 Nm 10%)
2. Connect the power cable.
Lay the wires according to the interconnection plan onto the terminal
block X1 and X2.
3. Assemble the plug-in interlock on encoder connector X3.
DOK-MOTOR*-MKE*GEN2***-PR06-EN-P
Rexroth MKE Synchronous Motors for Potentially Explosive Areas acc. to ATEX and UL/CSA
Bosch Rexroth AG
115/135
Installation