background image

1

Internal gear pump PGH5

1.1

ISO4017-M16X40-8.8 (tightening torque 210 Nm)

1.2

ISO7090-16-200HV

1.3

DIN580-M10

2

Adapter flange

3

Pump foot (option)

3.1 / 3.3 ISO7090-16-200HV
3.2

ISO4762-M16X70-8.8 (tightening torque 210 Nm)

3.4

ISO4032-M16-8

4

Synchronous motor MSK133

4.1

ISO7090-16-200HV

4.2

ISO4762-M16X40-8.8 (tightening torque 210 Nm)

4.3

DIN580-M12

5

Damping rail (option)

5.1

ISO4017-M10X30-8.8 (tightening torque 50 Nm)

5.2

ISO7089-10-200HV

Mount motor-pump unit MPA01 from components

The figure shows mounting of motors in design "SA" (air cooling). The
mounting of motors in "FN" design (liquid cooling) is identically.
1. Screw on damping rails (5) on the motor.

In case of design without damping rails, this mounting step is not
applied.
To reach the fastening holes, remove the lower air guides to
mount the damping rails in the case of motors with fan. Fasten
the damping rails (5) with the screws (5.1) and washers (5.2) on
the motor. Tightening torque 50 Nm, lock screw connection with
Loctite 243®. Remount the air guides.

2. Mount the adapter flange (2).

With design without adapter flange, this mounting step is not ap-
plied.
Screw the adapter flange (2) on the motor (4) with socket head
screws (4.2) and washers (4.1). Tightening torque 210 Nm, lock
screw connection with Loctite 243®.

3. Screw the pump with the motor.

Use adaquate lifting tools.

2

PGH5 - MSK133 - Air / Liquid Cooling |  Motor-Pump Unit MPA01

Bosch Rexroth AG, Edition 03 , R911341600, DOK-SYTROX-MPA01*M13**-AS03-EN-P

Summary of Contents for Rexroth PGH5-MSK133-Air

Page 1: ...es and spare parts which are permitted by the manufacturer to prevent from risk of injury due to unsuitable spare parts Qualified personell Mounting and installing of motor pump units MPA01 must be done by qualified personell or competent persons A person is qualified if knowledge or experiences of respective standards and regulations ex ists Assigned work must be evaluated and possible danger be ...

Page 2: ...w on damping rails 5 on the motor In case of design without damping rails this mounting step is not applied To reach the fastening holes remove the lower air guides to mount the damping rails in the case of motors with fan Fasten the damping rails 5 with the screws 5 1 and washers 5 2 on the motor Tightening torque 50 Nm lock screw connection with Loctite 243 Remount the air guides 2 Mount the ada...

Page 3: ...A MSK133 FN Nominal size B C D E Weight kg 91 6 111 0 127 0 146 0 Weight MSK motors Frame size MSK133 Adapter flange Pump foot Damping rails Weight kg 9 3 18 6 17 Weight motor components The specified weights apply to the components only weights of mo tor pump combinations add up from the single values Ensure a suffiently dimensioned loading capacity of the lifting tools so that the weight of the ...

Page 4: ...ir guides on the motor Tightening tor que of fastening screws of air guides 6 1 Nm Foot fastening motor A with damping rails The motor must be fastened with screws 4x M10 by the customer For the connection dimensions refer to the dimension sheet For mounting remove the lower air guide of motors with fan to reach the fastening holes 4x Ø12 mm 1 For dismounting loosen the 3 fastening screws M5x12 of...

Page 5: ...Phone 49 9352 18 0 service svc boschrexroth de www boschrexroth com electrics Copyright Bosch Rexroth AG 2016 This document as well as the data specifications and other information set forth in it are the exclusive property of Bosch Rexroth AG It may not be re produced or given to third parties without its consent R911341600 R911341600 AC ...

Reviews: