22
/48
Analog amplifier RA
| Installation
Bosch Rexroth AG, RE 95230-B/2021-12-01
Fig� 7: Mating connector, complete set
The enclosed contacts are suitable for vehicle cables type FLY (old designation
FLK) for the wire size range of 0.5 … 1 mm
2
and an insulation of 2.0 … 2.7 mm.
If other vehicle lines (e.g. FLRY; old designation FLK-R) are used, the corresponding
contacts 927771-3 (band) or 927779-3 (loose) and suitable tools must be purchased
from the trade.
Individual wires and/or several lines are to be introduced into the sleeve of the
connector by bundling them in a PVC insulation hose of 15 to 18 mm in order to
achieve type of protection IP65.
Fig� 8: correct
Fig� 9: incorrect
It is recommended to start assembling the lines from the connector.
1�
Pull the wires and/or lines into the insulation hose.
– Let the wires protrude at least 12 cm over the insulation hose end.
– In case of multi-wire lines, insulate the insulation of the outer sheath
approx. 0.5 cm after the insulation hose end.
Procedure