40
/48
Analog amplifier RA
| Installation
Bosch Rexroth AG, RE 95230-B/2021-12-01
• Switching solenoids at the switched output of the analog amplifier do not have
to be connected to a spark-suppression diode.
• Other inductive consumers that are in the system but not connected to the
analog amplifier must be connected to spark-suppression diodes. This also
applies to relays if they have the same supply as the amplifier.
7�5�5 Electrically connecting the analog amplifier
1�
Make sure that the connector of the analog amplifier and the mating connector
of the wire harness are compatible. For pin assignment, see chapter 7.4.4
"Pin assignment" on page 31.
2�
Make sure that the mating connector of the wire harness is in de-energized
condition.
3�
Connect the mating connector of the wire harness to the analog amplifier
connector until it engages noticeably and observe the correct plug-in position.