14/96
Pressure and flow control system SYDFE1 series 2X, 3X
| General notes on damage to property and damage to the product
Bosch Rexroth AG, Edition 10.2021, RE 30011-B
3 General notes on damage
to property and damage to
the product
NOTICE
Inadmissible mechanical load!
Hitting or impulsive forces on the drive shaft or the pilot valve can damage or
even destroy the SYDFE1 control system.
▶ Do not hit on the coupling or drive shaft of the axial piston unit.
▶ Do not set/place the axial piston unit on the drive shaft or the pilot valve.
▶ Never use the SYDFE1 control system as a handle or step. Do not place/put
any objects on top of it.
Foreign bodies and contaminants in the control system!
Risk of damage, wear and malfunctions due to ingress of dirt and foreign
particles.
▶ During installation, ensure utmost cleanliness in order to prevent foreign
particles such as welding beads or metal chips from getting into the hydraulic
lines.
▶ Before commissioning, make sure that all hydraulic connections are tight
and that all seals and closing elements of plug-in connections are correctly
installed and not damaged.
▶ Take care that no cleaning agents enter the hydraulic system.
▶ Do not use cotton waste or linty cloths for cleaning.
Wear!
Wear may lead to malfunctions.
▶ Carry out the prescribed maintenance work at the time intervals specified in
the operating instructions.
Environmentally harmful hydraulic fluid!
Leaking hydraulic fluid leads to environmental pollution.
▶ Immediately remedy any leakage.
▶ Dispose of the hydraulic fluid in accordance with the national regulations in
your country.
Insufficient pressure!
If the pressure falls below the specified value, damage can occur or the product
be destroyed.
▶ Make sure that the pressure cannot fall under the prescribed minimum value.
Insufficient hydraulic fluid!
If you commission or operate the SYDFE1 control system without or with
insufficient hydraulic fluid, the control system is immediately damaged or even
destroyed.
▶ When commissioning or re-commissioning a machine or system, make
certain that the housing chamber as well as the suction and working lines
of the control system are filled with hydraulic fluid and remain filled during
operation.