30/96
Pressure and flow control system SYDFE1 series 2X, 3X
| Product description
Bosch Rexroth AG, Edition 10.2021, RE 30011-B
Splined shaft profiles depend on the size (NG) of the pump. Two different splined
shaft profiles are available in conjunction with “SYDFEx“ :
• “S“-profile for NG18, NG100, NG140 and NG180
• “R“-profile for NG28 ... 71
When compared with the “S”-profile, the “R”-profile features further improved
properties with regard to the torque carrying capacity of the shaft. This version
represents the optimum for a wide variety of applications.
5.10 SPOOL VARIANT OF THE VT-DFPE-X-2X PILOT VALVE
The standard spool according to the ordering code is spool type “A“ (360° spool).
Especially for press applications (280 bar) type “C” (4-groove spool) has proven in
practice in conjunction with the SYDFE1 control system.
On older systems, a 2-groove spool “B” was often employed. However, this spool
should no longer be used for new applications due its poor dynamics.
5.11 FUNCTIONS OF CONTROL ELECTRONICS VT 5041-3X
5.11.1 Enable
WARNING
Uncontrolled machine movements!
Risk of severe injury! The enable does not represent a safety function!
▶ All further, safety-relevant interventions must be made by the higher-level
control (e.g. switching the drive motor OFF, closing the shut-off valves, ....).
The enable for the control electronics is granted by applying 24 V to switching
input 26c. This activates the output stage of the VT 5041-3X, i.e. the pilot valve.
The presence of the enable is signaled by LED “En.“ on the front panel.
The following options are provided for connecting enable input 26c:
• Controlling by higher-level control (to be preferred)
• Fixed wire bridge
• Via relay
• Conventional switch
The withdrawal of the enable signal at 26c deactivates the valve output stage of
the control electronics and causes the pilot valve to go to a defined position. The
same effect is achieved by switching off the voltage supply.
This has the following consequences:
• With an
actuating system
with internal supply
the pump swivels to the zero
stroke position.
Zero stroke = minimum pressure generated by a pump with internal supply
• In contrast to this, a pump with
actuating system with external supply
swivels
to the mechanical limit stop “-100 %“.
The enable is always required for normal operation. In the event of a fault, such
a fault can be cleared by withdrawing and re-applying the enable. Clearing of the
fault message is also possible by switching the supply voltage off and then on
again.
Splined shaft