RE 30011-B, Edition 10.2021, Bosch Rexroth AG
Maintenance and repair |
Pressure and flow control system SYDFE1 series 2X, 3X
73/96
10 Maintenance and repair
10.1 CLEANING AND CARE
NOTICE
Solvents and aggressive cleaning agents!
Aggressive cleaning agents may damage the seals of the SYDFE1 control system
and make them age faster.
▶ Never use solvents or aggressive cleaning agents.
Ingress of dirt and liquids!
This will result in the fact that the safe operation of the SYDFE1 control system
can no longer be ensured.
▶ When carrying out any work on the SYDFE1 control system observe strictest
cleanliness.
▶ Do not use high-pressure cleaners.
For cleaning and care of the SYDFE1 control system, observe the following:
▶ Plug all openings with suitable protective caps/devices.
▶ Check that all seals and plugs of the plug-in connections are securely seated to
ensure that no moisture can enter the SYDFE1 control system during cleaning.
▶ Use only water and, if necessary, a mild detergent to clean the SYDFE1 control
system.
▶ Remove external coarse dirt and keep sensitive and important parts like
solenoids, valves and indicators clean.
10.2 INSPECTION
In order that the SYDFE1 control system will work reliably and for a long time,
Rexroth recommends that you inspect the SYDFE1 control system regularly at the
following maintenance intervals and document the following operating conditions:
Table 17: Inspection schedule
Work to be carried out
Interval
Hydraulic
system
Check level of hydraulic fluid in the tank.
Daily
Check operating temperature (comparable load state).
Weekly
Analyze quality of the hydraulic fluid.
Annually or every
2000 h (whichever
occurs first)