RE 30011-B, Edition 10.2021, Bosch Rexroth AG
Troubleshooting |
Pressure and flow control system SYDFE1 series 2X, 3X
87/96
Table 19: Malfunction table for SYDFE1 control systems
Malfunction
Possible cause
Remedy
Pressure too low (< 12 bar)
Weighting of the actual pressure value is
incorrectly set
Diagnostics: Pressure command value (6c/4c)
and actual pressure value normalized (24c)
are equal and can be regulated
Adjust pressure command value and/or
actual pressure value (see page 68)
Replace pressure transducer
Change the place of installation of the
pressure transducer (do not install
upstream of the pre-load valve; where
appropriate, close to the consumer)
Pressure transducer defective
Diagnostics: Measure signal from PT and
compare with indication on the pressure gauge
Replace pressure transducer
Control system does not work in closed-loop
pressure control
Diagnostics: Pressure command value (6c/4c)
is less than actual value normalized (24c).
Increase swivel angle command value
Increase power limit (see page 70)
Check that the hydraulic system is leak-free
and there is no excessive oil consumption
Pilot valve defective
Replace pilot valve
Pressure too high
Weighting of the actual pressure value is
incorrectly set
Diagnostics: Pressure command value (6c/4c)
and actual pressure value normalized (24c)
are equal and can be regulated
Adjust pressure command value and/or
actual pressure value (see page 68)
Replace pressure transducer
Replace control electronics VT 5041-3X
Pressure transducer defective/not connected
Diagnostics: Measure signal from PT and
compare with indication on the pressure gauge
Connect pressure transducer correctly/
replace
Insufficient flow
Pressure controller active
Increase pressure command value
Power limitation (optional) active
Increase power command value (optional)
(see page 70)
Actual swivel angle acquisition improperly set
Adjust swivel angle sensor (see page 70)
Drive speed too low (slip, incorrect frequency,
wrong motor)
Machine or system manufacturer
Damage to the pump (excessive pump
leakage)
Replace pump
Wear/mechanical damage to the control
system
Replace control system, contact Rexroth
Service
Drive motor shuts down due to
overloading
Excessive power consumption of the pump
Reduce power command values (optional
(see page 70)
Reduce swivel angle command value
Test actual pressure value acquisition (see
page 68)
Overcurrent protection of motor does not work
properly
Check setting and function
Spool jams in pilot valve
Diagnostics: Disconnect central plug-in
connector X1 or supply voltage from pilot
valve and test whether the motor is still
overloaded
Replace pilot valve, see page 75
Actual swivel value acquisition maladjusted or
does not work
Check actual swivel angle acquisition (see
VT 5041-3X defective
Replace control electronics VT 5041-3X