Pressure and flow control system SYDFE1 series 2X, 3X
| Technical data
Bosch Rexroth AG, Edition 10.2021, RE 30011-B
Table 19: Malfunction table for SYDFE1 control systems
Malfunction
Possible cause
Remedy
Hydraulic fluid temperature too
high
Inlet temperature at control system too high
Inspect system, e.g. for malfunction of the
cooler, insufficient hydraulic fluid in the
tank
Pre-load valve opens
Diagnostics: Pipe to the tank heats up
Pressure must be lower than the cracking
pressure of the pre-load valve. Keep
overshoots and pressure pulsation to a
minimum.
Malfunction of pressure/pilot valves (e.g. high
pressure relief valve, pressure cut-off, pressure
controller)
Contact Rexroth Service
Control system worn out
Replace control system, contact Rexroth
Service