RE 30011-B, Edition 10.2021, Bosch Rexroth AG
Product description |
Pressure and flow control system SYDFE1 series 2X, 3X
21/96
5.3.2 Pressure control
WARNING
Forcefully ejected parts and hydraulic fluid jet!
Risk of severe injury! The electrical pressure control does not assume a pressure
relief function.
▶ Make certain that the maximum operating pressure is not exceeded.
▶ If a pre-load valve is installed, you can use its pressure relief function. If no
pre-load valve is installed, provide a pressure relief valve, the pressure setting
of which is 10 % (recommended) higher than the operating pressure, in the
pressure line. Operating the system without this valve can lead to malfunction.
If the axis is to operate in this mode, an analog signal within the range from
+10.0 V to U
B
can be assigned to the swivel angle command value and used
to deactivate the swivel angle controller. However, for some applications,
it is advantageous to limit the permitted swiveling range of the pump by
feedforwarding a suitable swivel angle command value. However, this command
value must be sufficiently great in order that the pressure controller can swivel out
the pump to the required extent.
5.3.3 Power limitation (optional) with VT 5041-3X/3...
This version allows optimum matching with the performance limits of the drive
motor.
Due to the relationship of P ≈ α
comm
* p
act
the power controller intervenes with a
reducing/limiting effect (power hyperbola) via the swivel angle command value
branch, if required.
0
100
0
100
Power
Actual pressure value [%]
Ma
x. flo
w [%]
Fig. 6: Power limitation