RE 30011-B, Edition 10.2021, Bosch Rexroth AG
Commissioning |
Pressure and flow control system SYDFE1 series 2X, 3X
59/96
8 Commissioning
WARNING
Working in the danger zone of a machine or system!
Risk of severe injury due to unsafe working.
▶ The machine or system may only be commissioned when safe working is
ensured.
▶ Pay attention to and eliminate potential danger sources before commissioning
the machine or system.
▶ Nobody may stand in the danger zone of the machine or system.
▶ The emergency stop button for the machine or system must be within the
operator’s reach.
▶ Always strictly observe the instructions of the machine or system manufacturer
during commissioning.
Uncontrolled system behavior!
Non-connected electrical and hydraulic connections can cause malfunctions and
hydraulic fluid jets to be ejected, which can injure you.
▶ Only commission a completely installed product.
NOTICE
Loss of protection class due to missing seals and plugs!
Liquids and foreign particles may penetrate and damage the product.
▶ Before commissioning, make sure that all seals and plugs of plug-in
connections are tight.
Ingress of dirt!
Damage to the SYDFE1 control system! Contamination of the hydraulic fluid
results in wear and malfunction. In particular foreign bodes such as welding
beads and metal chips in the hydraulic lines can damage the SYDFE1 control
system.
▶ Observe utmost cleanliness during commissioning.
▶ When closing measuring ports, make sure that no contamination can enter.
Insufficient hydraulic fluid!
Insufficient amounts of hydraulic fluid can lead to destruction of the product.
▶ Make certain that the case of the SYDFE1 control system is filled with
hydraulic fluid during commissioning and in operation. This must also be
observed during longer periods of standstill as the SYDFE1 control system
may empty empty via the hydraulic lines.