After expiration of the maximum storage time, we recommend that you have the
SY(H)DFED control system inspected by your responsible Rexroth Service
partner.
Should you have questions regarding spare parts, contact your Rexroth Service
partner responsible for SY(H)DFED control systems, see chapter 10.5“Spare
If a dismounted SY(H)DFED control system is to be stored, it must be preserved
against corrosion for the duration of storage.
The following instructions only refer to SY(H)DFED control systems, which are
operated with a hydraulic fluid based on mineral oil. Other hydraulic fluids
require preservation methods that are specifically tailored to them. In such a
case, consult with the Rexroth Service (for address, see chapter 10.5 “Spare
Rexroth recommends the following proceeding:
1.
Drain the SY(H)DFED control system completely.
2.
Clean the SY(H)DFED control system, see also chapter 10.1 “Cleaning and
3.
For storage times up to 12 months: Wet the SY(H)DFED control system
internally by filling in about 100 ml of mineral oil.
For storage times up to 24 months: Fill the SY(H)DFED control system with
anti-corrosion agent VCI 329 (20 ml).
Filling via the case drain port.
4.
Plug all ports air-tight.
5.
Wet non-varnished external metal surfaces of the SY(H)DFED control system
with a suitable anti-corrosion agent.
6.
Pack the SY(H)DFED control system air-tight together with a desiccant in an
anti-corrosion foil.
7.
Protect the SY(H)DFED control system against impacts during storage. For
further conditions, see “Requirements“ above.
▶ In each case, please observe any applicable provisions and laws regarding the
handling of substances hazardous to water or to health.
Following demounting