40/96
SYDFED-2X, SYDFED-3X, SYHDFED-1X
| Transport and storage
Bosch Rexroth AG, Edition 11.2021, RE 30017-B
CAUTION
! Risk of injury!
During transport with a lifting device, the control system can fall out of the lifting
strap and cause injuries.
▶ Hold the control system with your hands to prevent it from falling out of the
lifting strap.
▶ Use the widest possible lifting strap.
Fig. 17: Transport with lifting strap
Transport damage must be reported to your contact in the sales organization
within one week. You can find the addresses of our sales locations on the
Internet at:
http://www.boschrexroth.com
6.2
STORING THE SY(H)DFED CONTROL SYSTEM
Some SY(H)DFED control systems are shipped in an anti-corrosion foil (max.
storage time: 12 months). Without anti-corrosion foil, corrosion protection is
limited to transport (a few days). If these control systems are to be stored, then
you must provide preservation like for storage after demounting (see below).
• Do not store the hydraulic component outdoors but in a well ventilated room.
• The storage rooms must be dry and free from corrosive materials and gasses.
• For the permissible storage temperature, please refer to the relevant data sheet.
• Avoid intense light.
• Do not stack SY(H)DFED control systems and store them shock-proof and slip-
proof.
• SY(H)DFED control systems are very heavy (see also Table 9 “Weights“ on page
38). In this connection observe the admissible load-bearing capacities of your
storage system.
▶ Check the SY(H)DFED control system monthly for proper storage.
Procedure after expiration of the maximum storage time:
1.
Check the entire SY(H)DFED control system for damage and corrosion prior to
installation.
2
. Check the SY(H)DFED control system for proper function and leaks during a
test run.
3
. Replace the shaft seal ring when the storage time of 24 months is exceeded.
Requirement