RE 30017-B, Edition 11.2021, Bosch Rexroth AG
Commissioning |
SYDFED-2X, SYDFED-3X, SYHDFED-1X
61/96
Fig. 23: Connection selection
To establish a connection to the selected system, click the OK button.
Should EtherCAT or VARAN be activated as field bus system, you can deactivate
these bus systems for direct communication with IndraWorks. To this end, send
the deactivation command by clicking the button “EtherCAT/VARAN
Deactivation”. Alternatively, with these bus systems you can access the SY(H)
DFED system directly via the Engineering port of the control.
8.1.5 Making basic settings on the control electronics
To be able to adjust the control electronics, you must have installed the
engineering tool IndraWorks. The user must configure the SY(H)DFED control
system according to the customer-specific requirements. This refers mainly to the
following settings:
• Settings for the pressure transducer
• Settings for the swivel angle sensor
• Entry of pump and motor values
To set the enable for a test during commissioning, the use the Easy Startup Mode.
It is configured and started using IndraWorks.