RE 30017-B, Edition 11.2021, Bosch Rexroth AG
Commissioning |
SYDFED-2X, SYDFED-3X, SYHDFED-1X
71/96
Fig. 33: Calibration
For calibrating the SY(H)DFED control system, the hydraulic fluid must have
reached operating temperature.
8.2
RECOMMISSIONING AFTER STANDSTILL
Depending on the installation and ambient conditions, changes may occur in the
system which make recommissioning necessary.
Among others, the following criteria may result in the necessity for
recommissioning:
• Air in the hydraulic system
• Water in the hydraulic system
• Aged hydraulic fluid
• Other contamination
▶ For recommissioning, proceed as described in chapter 8.1 “Initial
commissioning” on page 59.
8.3
RUNNING-IN PHASE
NOTICE
Viscosity too low!
Risk of damage! The increased temperature of the hydraulic fluid during the
running-in phase can cause the viscosity to drop to impermissible levels.
▶ Monitor the operating temperature during the running-in phase.
▶ Reduce the loading (pressure, speed) of the SY(H)DFED control system, if
impermissible operating temperatures and/or viscosities occur.