13.4.4
Motor or machine table creates vibrations
State
Vibrations on the motor are audible and noticeable.
Possible cause
1.
Driven machine elements are insufficiently coupled or damaged
2.
Motor bearing worn or defective
Available bearing lifetime or grease lifetime expired
3.
Motor fastening loosened
4.
Drive system is instable in terms of regulation
Counter measures
1.
Contact the machine manufacturer
2.
Contact the machine manufacturer
3.
Check mechanical connections. Do not use damaged parts. Contact the
machine manufacturer
4.
Check parameterization of drive system.
Bosch Rexroth AG
DOK-SYTROX-MPES2******-IT01-EN-P
Rexroth Sytronix FcP 50xx/70xx Motor-Pump Unit MPES2
96/143
Troubleshooting