6.5 Digital Input
Code
Name
Setting Range
Default
Min.
Attri.
F2.16 X1 input
0: No function assigned from ASF
1: Pressure command selection bit0
2: Pressure command selection bit1
3: p/Q parameter set selection
4: Flow command selection
5: Master / slave mode switch
6: Oil filter warning
7: Oil level warning
8: Oil temperature warning
9: Oil filter error
10: Oil level error
11: Oil temperature error
12: Oil level / temperature error
13: Oil filter warning inverse
14: Oil level warning inverse
15: Oil filter error inverse
16: Oil level / temperature error inverse
17: Reserved
18: Reserved
19: Reserved
20: Pressure drop compensation trigger
21: Pressure overshoot compensation
trigger
22: Enable for myCro
0
(RUN)
-
Stop
F2.17 X2 input
0
(Error reset)
-
Stop
F2.18 X3 input
0
-
Stop
F2.19 X4 input
0
-
Stop
F2.20 X5 input
0
-
Stop
F2.21 EX1 input
0
-
Stop
F2.22 EX2 input
0
-
Stop
F2.23 EX3 input
0
-
Stop
F2.24 EX4 input
0
-
Stop
F2.25 EX5 input
Tab. 6-4: Digital input parameter list
The default setting of terminal X1...X5, EX1...EX5 in ASF is ''0''. This means no
function from ASF is assigned, only EFC firmware functions assigned are active.
Part of the EFC firmware parameters, including [E1.01] = 34 (X2 set to ''Reset''),
will be pre-set automatically in ASF.
The digital inputs F2.16...F2.25 are mutually exclusive, which therefore do not al-
low for any identical setting (except 0) between the parameters. When a repea-
ted non-zero value entered, the former will reset to 0 automatically, i.e. the last
entered takes effective.