17.1.7
MSK133D Technical Data
Data Sheet
Designation
Symbol
Unit
MSK133D-0202-SA
MSK133D-0203-FN
Continuous torque at standstill, sur‐
face
M
0_S
Nm
250.0
---
Continuous current at standstill, sur‐
face
I
0_S(rms)
A
100.0
---
Standstill continuous torque liquid
M
0_L
Nm
---
290.0
Continuous standstill current liquid
I
0_L(rms)
A
---
122.2
Maximum torque
M
max
Nm
520.0
500.0
Maximum current
I
max(rms)
A
265.0
Torque constant at 20 ℃
K
M_N
Nm/A
2.45
Voltage constant at 20 °C
1)
K
EMK_1000
V/1000
min
-1
155.8
Winding resistance at 20 ℃
R
12
Ohm
0.075
Winding inductivity
L
12
mH
6.1
6
Discharge capacity of the component
C
dis
nF
16.4
18.4
Number of pole pairs
o
-
3
Moment of inertia of the rotor
J
rot
kg*m
2
0.07800
Thermal time constant
T
th_nom
min
18.2
8.0
Maximum velocity
n
max
min
-1
3300
Sound pressure level
L
P
dB[A]
smaller than 78
Mass
m
kg
127.0
Surrounding air temperature during
operation
T
amb
°C
0 ... 40
Protection class acc. to EN 60034
-
-
IP65
Insulation class according to EN
60034-1
T.CL.
-
155
Data liquid cooling
Power loss to be dissipated
P
V
kW
---
3.10
Coolant inlet temperature
T
in
°C
---
10...40
Allowed coolant temperature rise at P
V
ΔT
max
K
---
8
Necessary coolant flow at P
V
Q
min
l/min
---
6.0
Pressure loss at Q
min
Δp
bar
---
smaller than 0.9
Maximum allowed inlet pressure
p
max
bar
---
6.0
Volume of coolant duct
V
cool
u
---
0.21
Material coolant duct
Stainless steel
Latest amendment: 2013-11-25
1)
Manufacturing tolerance ±5 %
Tab.17-7:
MSK - Technical data
DOK-SYTROX-MPA01******-IT02-EN-P
Rexroth Sytronix SvP 70xx Motor-Pump Unit MPA01
Bosch Rexroth AG
103/123
Technical Data