7.5
Installation
7.5.1
Permitted Installation Positions of the Motor-Pump Unit
B3
B5
V1
mpa01-0008el
The assembly of motor-pump units can be made in foot or flange mounting.
Allowed installation positions according to EN 60037-7 are IM B3, IM B5 and
IM V1. Vertical installation IM V3 (motor under the pump) is not permitted.
7.5.2
Installation MPA01-PGH4-MSK101 Air Cooling
The screw connection must be adjusted to the installation situation (screw-
length, property class, screw-in depth, material, ...). The dimensioning of the
screw connection is in the responsibility of the customer.
●
Assemble in dry, dust free environment.
●
Ensure a burr-free machine-side contact surface.
●
Securely screw the motor-pump unit with the machine construction.
Fastening
Hole
ø [mm]
Bolt size-
ISO-grade
Washer
Foot
14
M12
Yes
Flange
13,5
M12
-
Tab.7-1:
MPA accessory for fastening
4x M12
4x M12
mpa01-0004mo
Fig.7-8:
Assemble motor-pump unit MPA01 into the construction.
7.5.3
Installation MPA01-PGH5-MSK133 Air / Liquid Cooling
The screw connection must be adjusted to the installation situation (screw-
length, property class, screw-in depth, material, ...). The dimensioning of the
screw connection is in the responsibility of the customer.
●
Assemble in dry, dust free environment.
●
Ensure a burr-free machine-side contact surface.
●
Securely screw the motor-pump-unit with the machine construction.
Bosch Rexroth AG
DOK-SYTROX-MPA01******-IT02-EN-P
Rexroth Sytronix SvP 70xx Motor-Pump Unit MPA01
48/123
Assembly
LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01