3 608 878 300
Tightening Technology |
Bosch Rexroth AG 127
System 350
| 3 608 878 300/2019-03
Application-specific signals are, e.g., also suitable for looping through signals: A signal can be read via a
24-V interface of the tightening controller (
SE AppIn
0-15) and output to the partner controller via
PROFIBUS (
SE AppOut
0-15).
The application-specific input signals are mirrored to the outputs.
AutoBackup
Auto backup: Automatic data backup
This signal is available from version V2.600 of the
Rexroth Tightening System 350
.
Input signal used for:
•
Compact system (
AutoBackup
)
•
Communication unit (
AutoBackup
)
Setting this signal to “High” starts the automatic backup if the
Auto backup/restore
function is
configured in the operating system, see
Automatic data backup with backup/restore function
Example
SE
A signal can be read via a 24-V interface of the tightening controller (
SEAppIn
0-15) and output to the
partner controller via PROFIBUS (
SE AppOut
0-15).
Example
KE
A signal can, e.g., be read by the KE via a 24-V interface (signal
KE AppIn
0-15) and then output to the
partner controller via this interface, with
KE AppOut
0-15.
The inputs are transferred from the KE to the SE, irrespective of enabling (
Ch x.y SEn
).
Summary of Contents for Rexroth Tightening System 350
Page 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Page 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...