NOKAcByps
Not OK acknowledge bypass: NOK-acknowledgement with deselected spindles
This signal is available from version V2.200 of the
Rexroth Tightening System 350
.
Input signal used for:
•
Communication unit in application operation (
FO x NOKAc
Byps)
The tightening system also features the option of preventing further starts after NOK tightening
(
NOKByps
to "high"). Restart is not possible before the
NOKAcByps
signal is set to "low".
This function is active if the
NOKAcByps
signal is set to "high" at start time. After NOK tightening
(
NOKByps
"high"), the tightening system is ready to be restarted by resetting the
NOKAcByps
signal to
"low". The system is ready to start when the
InCy
or
InCyCcw
signal is shown to be "low". Setting
NOKAcByps
to "low" also resets
NOKByps
.
Prog0-7
Program 0-7 Program selection
Input signal used for:
•
Tightening channel (
Prog0-7
)
•
Communication unit in single-channel operation (
CH x.y Prog0-7
)
Only bits 0 to 5 can be used. Bits 6 and 7 are reserved for future versions.
The binary encoded program number is forwarded to the tightening controller through these six inputs.
The program number is valid within the tightening controller if the program acknowledgement signals
correspond to the selected program. The program number must be selected and acknowledged by the
system before the start of the tightening.
If
NOKAc
is assigned to input 0.3 in the PLC table of a tightening channel with ErgoSpin, the signal is
inverted, i.e. the signal changes to "low" when the ErgoSpin tool button is pushed, and to "high" when
the tool button is released.
While
Cw
/
Ccw
is set to "high", the
NOKAc
signal must not be set to "low" and reset to "high" as
InCy
/
InCyCcw
is otherwise not reset.
While
Cw
/
Ccw
is set to "high", the
NOKAcByps
signal must not be set to "low" and reset to "high" as
InCy
/
InCyCcw
is otherwise not reset.
The
NOKAcByps
must be reset after the
Cw
or
Ccw
start signal has been reset to set the
InCy
/
InCyCcw
signal to "low".
If the OK/NOK counter is configured for the program, the counter will be automatically selected when the
program is selected.
Tightening
program
Prog5
Prog4
Prog3
Prog2
Prog1
Prog0
0
Low
Low
Low
Low
Low
Low
1
Low
Low
Low
Low
Low
High
2
Low
Low
Low
Low
High
Low
3
Low
Low
Low
Low
High
High
.
.
.
.
.
.
.
.
.
.
.
.
.
.
99
High
Low
High
High
High
High
Summary of Contents for Rexroth Tightening System 350
Page 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Page 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...