3 608 878 300
Tightening Technology |
Bosch Rexroth AG 141
System 350
| 3 608 878 300/2019-03
AppOut 0-15
Application Out Bit 0-15: Application-specific output signal
Output signal used for:
•
Tightening channel (
AppOut
)
•
Communication unit in single-channel operation (
CH x.y AppOut, CH x.y SE AppOut
)
•
Communication unit in application operation (
KE AppOut, FO x SE AppOut
)
See
SE AppIn 0-15
The
AppOut 0
to
AppOut 7
signals can be applied to the HVO module as desired.
BoxNut LED0-7Ack
Box Nut LED acknowledge: Acknowledges switch-on of LED0-7 in the socket tray
Output signal used for:
•
Tightening channel (
BoxNut LEDxAck
)
Using this signal, the Tightening System350 activates the corresponding LED(0…7) of the socket tray.
Also refer to figure
.
BoxNut SelAck0-7
Box Nut Selected acknowledge: Acknowledges selection of socket 0-7 from the socket tray
Output signal used for:
•
Tightening channel (
BoxNut SelAckx
)
Using this signal, the Tightening System350 informs a superior system on which socket (0…7) has been
selected from the socket tray. Also refer to figure
BypsAc
Bypass acknowledge: Acknowledges deselection of the tightening spindle/acknowledges
bypass mode of the tightening cell
Output signal used for:
•
Tightening channel (
BypsAc
)
•
Communication unit in single-channel operation (
CH x.y BypsAc
)
•
Communication unit in application operation (
FC BypsAc
)
Kanal: This signal indicates that the respective tightening controller x.y was deselected with
Ch x.y Byps
or using the operating program.
Application: This signal is "high" if at least one tightening cell spindle was set to bypass mode and
bypassed accordingly.
CwAck
Clock wise acknowledge: Acknowledges a start
Output signal used for:
•
Tightening channel (
CwAck
)
•
Communication unit in single-channel operation (
CH x.y CwAck
)
This signal serves to acknowledge the start of the selected tightening program.
CcwAck
Counter clock wise acknowledge: Acknowledges a loosening operation
Output signal used for:
•
Tightening channel (
CcwAck
)
•
Communication unit in single-channel operation (
CH x.y CcwAck
)
This signal confirms that the tightening program No. 99 loosen was started in one tightening channel or
all cannels of the selected tightening application.
In the Tightening channel configuration, under
Socket tray coding
the required
Bit pattern
or
Decimal
coding for the socket tray used has to be configured.
Summary of Contents for Rexroth Tightening System 350
Page 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Page 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...