3 608 878 300
Tightening Technology |
Bosch Rexroth AG 147
System 350
| 3 608 878 300/2019-03
InCyEv
In
Cycle Evaluation: Time period elapsing while tightening is active, including completed
evaluation
This signal is available as of version V2.300 of the
Rexroth Tightening System 350
.
Output signal used for:
•
Tightening channel (
InCyEv
)
•
Communication unit in single-channel operation (
CH x.y InCyEv
)
The
InCyEv
signal shows the period elapsing from the time when tightening is started until evaluation is
completed.
It is set to "high" along with
InCy
. Once
OK
or
NOK
changes to "high",
InCyEv
is set to "low". While there
is no evaluation ("Play at start switch"),
InCyCm
is set to "low" no later than when
CyCmp
changes to
"high".
InfoTool
Information tool: Limit value for prewarning reached
This signal is available from version V2.600 of the
Rexroth Tightening System 350
.
Output signal used for:
•
Tightening channel (
InfoTool
)
This signal turns to "high" when a limit value for the maintenance prewarning set in the channel
configuration has been reached. The signal is set to "low" if monitoring is deactivated or if the set limit
value is reset.
Job Ack 0-7
Job acknowledge 0-7: Acknowledges the selected job
This signal is available in the compact system as of version V2.300, KE as of V2.400 and SE as of
V2.500 of the
Rexroth Tightening System 350
.
Output signal used for:
•
Tightening channel: Compact system (
Job Ack0-7
)
•
Communication unit in single-channel operation (
CH x.y Job Ack0-7
)
•
Communication unit in application operation (
KE Job Ack0-7
)
The signal acknowledges the selected job.
Using this signal, the PLC can determine whether the job was selected successfully. The job number is
only valid if the acknowledgement corresponds to the selection. The controller always uses the
acknowledged job number as a basis for a tightening operation or application.
Job CyCmp
The job is finished
This signal is available in the compact system as of version V2.300, KE as of V2.400 and SE as of
V2.500 of the
Rexroth Tightening System 350
.
Output signal used for:
•
Tightening channel: Compact system (
Job CyCmp
)
•
Communication unit in single-channel operation (
CH x.y Job CyCmp
)
•
Communication unit in application operation (
KE Job CyCmp
)
Job CyCmp
= “high” signals the end of the job sequence and the job results processing. The controller(s)
is (are) ready for the next job.
Job Nok
Job Not OK: The job result is not okay
This signal is available in the compact system as of version V2.300, KE as of V2.400 and SE as of
V2.500 of the
Rexroth Tightening System 350
.
Output signal used for:
•
Tightening channel: Compact system (
Job NOK
)
•
Communication unit in single-channel operation (
CH x.y Job NOK
)
•
Communication unit in application operation (
KE Job NOK
)
Summary of Contents for Rexroth Tightening System 350
Page 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Page 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...