6.1.5.2
Special cases without actual and limit values
In the tightening system results values are present, but due to the error it is impossible to decide which
values are correct. This is why no actual and limit values are output for the step.
Table 6–8:
Causes for stopping without output of actual and limit values
Cause for stopping
SB (Stopped by)
Quality code (QC)
Description
SB 18
System error
QC 137
Result NOK
Error redundancy torque
QC 138
Result NOK
Error redundancy angle
SB 18 means that the results from the primary and redundant transducer are (too) different. Which
transducer is faulty cannot be determined.