6.1.7
Chronological sequence of the tightening results data
6.1.7.1
ID code processing
ID codes are used whenever they are available before tightening is started (
FO x Cw, FO x CCw
or
CH x.y Cw
or
CH x.y CCw
). Preparation of ID codes for results is described
Fig. 6–4:
Chronological sequence of ID code processing with a tightening
ID codes are deleted if the
Delete ID code after start
setting has been activated in the BS350 operating
system.
Deleting the ID codes is recommended if the ID code is no longer required,
e. g. because the workpiece leaves the station respectively a new workpiece enters the station.
ID codes that have not been deleted will be reused.
(A)
Tightening application / tightening
(B)
ID code (ID code file available in the mass storage)
FO x Cw/
CH x.y Cw
Start
FO x InCy/
CH x.y InCy
Tightening active
FO x CyCmp/
CH x.y CyCmp
Process end
FO x ResRs/
CH x.y ResRs
Result reset
(1)
Cycle
(2)
Sequence
(3)
Result processing
(4)
ID code accepted by the KE controller (ID code will be deleted if set in the
operating system)
t
CH x.y Cw
H
L
CH x.y CyCmp
H
L
(2)
(1)
CH x.y ResRs
H
L
CH x.y lnCy
H
L
(3)
(4)
(B)
(A)
If active, the ID code is extended with a sequence number
Summary of Contents for Rexroth Tightening System 350
Page 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Page 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...