220
Bosch Rexroth AG
| Tightening Technology
3 608 878 300
System 350
| 3 608 878 300/2019-03
illustrate how the ID codes are used in the results output in relation to the ID code
availability. The ID code must be available before the start of the tightening application (
FO x Cw
) or the
tightening channel (
Ch x.y Cw
or
Ch x.y Ccw
).
6.2.2
Results output via FTP
6.2.2.1
Configuration of the FTP connection for results output
To configure the tightening system for results output via FTP:
1.
In the BS350 operating system, click
System
Tightening cell data.
2.
Click
FTP
.
3.
Select the
File system
index card.
Fig. 6–9:
Setting for results output via FTP
4.
In the
FTP server
menu, enter the necessary data for the FTP server where the results files should
be stored:
IP address / DNS:
You can either directly enter the FTP server's IP address or its name (must
already be listed in the DNS server).
Port:
Enter the TCP/IP port used for data transfer into this field. The admissible value range is
0...65535, the standard value is 21.
Example
ID code file contents (exactly the first 27 characters
were selected for masking):
AB 123.4_567,89.10C,ˆ%
‰
TEST
Resulting file name:
Ch_AB_123_4_567_89_10C____TEST.txt
Summary of Contents for Rexroth Tightening System 350
Page 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Page 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...