3 608 878 300
Tightening Technology |
Bosch Rexroth AG 291
System 350
| 3 608 878 300/2019-03
6.4.1.4
Layout of the data buffer for transferring ID-codes and results data
The data buffer in the interface module is divided into an input field and an output field. In the input field,
the partner controller stores the input control signals, the ID code and the IL data as Fieldbus master. In
the output field , the Fieldbus master receives the output control signals, the results data and the IL data.
All data (control signals, ID codes, tightening results) are located in a linear storage area at a location that
has been set by the configuration
. During project planning, the so-called master data file
(a GSD, EDS, or GSDML file, depending on the interface module) informs the partner controller on how
the data buffer is structured.
Table 6–45:
Allocation of the data buffer for IMpdp
Input field [in bytes]
Output field [in bytes]
Control signal
inputs
ID code
IL data
received
Control signal
Outputs
Results data
IL data
send
CS size
2 ... 8
0 ... 64
0 ... 198
2 ... 8 byte
0 ... 198
0 ... 198
KE size
2 ... 64
0 ... 198
0 ... 198
2 ... 64 byte
0 ... 198
0 ... 198
Total size
max. 200
max. 200
max. 400
Table 6–46:
Allocation of the data buffer for IMdev, IMmtcp, IMenip and IMenip2
Input field [in bytes]
Output field [in bytes]
Control signal
inputs
ID code
IL data
received
Control signal
Outputs
Results data
IL data
send
CS size
2 ... 8
0 ... 64
0 ... 254
2 ... 8 byte
0 ... 254
0 ... 254
KE size
2 ... 64
0 ... 254
0 ... 254
2 ... 64 byte
0 ... 254
0 ... 254
Total size
max. 256
max. 256
max. 512
Table 6–47:
Allocation of the data buffer for IMecat
Input field [in bytes]
Output field [in bytes]
Control signal
inputs
ID code
IL data
received
Control signal
Outputs
Results data
IL data
send
CS size
2 ... 8
0 ... 64
0 ... 252
2 ... 8 byte
0 ... 252
0 ... 252
KE size
2 ... 64
0 ... 252
0 ... 252
2 ... 64 byte
0 ... 252
0 ... 252
Total size
max. 254
max. 254
max. 508
Table 6–48:
Allocation of the data buffer for IMpnio and IMpnio2
Input field [in bytes]
Output field [in bytes]
Control signal
inputs
ID code
IL data
received
Control signal
Outputs
Results data
IL data
send
CS size
0 ... 8
0 ... 64
0 ... 256
0 ... 8 byte
0 ... 256
0 ... 256
KE size
0 ... 64
0 ... 256
0 ... 256
0 ... 64 byte
0 ... 256
0 ... 256
Total size
max. 256
max. 256
max. 512
Summary of Contents for Rexroth Tightening System 350
Page 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Page 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...