3 608 878 300
Tightening Technology |
Bosch Rexroth AG 299
System 350
| 3 608 878 300/2019-03
6.4.4.4
Configuration of results output on the control unit (for single-channel tightenings)
The results output can be configured flexibly. You can create your own individual results output using a
list with results characteristics, results values, and system parameters.
To set the results output:
1.
In the BS350 operating system, click
System
CS field bus data
The
CS field bus data
window will open.
Example
A torque value of 45.3 Nm is displayed as follows:
45.3 Nm / 0.00001 Nm
= 4530000 (decimal)
= 00000000010001010001111101010000 (binary)
= 00 45 1f 50 (hex)
and thus as follows in the byte stream of the results output:
Byte
n
n+1
n+2
n+3
Value
50
1f
45
00
In contrast, the output in the byte stream shown below should be interpreted as follows:
Byte
n
n+1
n+2
n+3
Value
70
5f
bc
00
= 00 bc 5f 70 (Hex)
= 00000000101111000101111101110000 (binary)
= 12345200 (decimal)
= 12345200 * 0.0001 degrees
= 1234.52 degrees
Although the INT32 numbers might reach a higher level of resolution (e.g. 5 digits after the decimal point
for torques), only the internally rounded floating decimal value is scaled accordingly; additional digits after
the decimal point are filled with "
0
".
If docu steps are not performed or if the tightening is aborted, no valid measurement value exists. In these
cases, 80 00 00 00 (Hex) is output as the measurement value.
Summary of Contents for Rexroth Tightening System 350
Page 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Page 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...