3 608 878 300
Tightening Technology |
Bosch Rexroth AG 305
System 350
| 3 608 878 300/2019-03
6.4.4.7
Evaluating the results output
The tightening result of a complete tightening process is always evaluated by means of the quality code
(QC). All other quality codes having the docu step no. 0:, 1:, etc. describe the results of the tightening
steps selected.
•
0: QC identifies the result of the tightening step run through previously
•
1: QC etc.: identifies the docu steps that can be selected (here: docu step 1)
Upper torque limit
cd a3 9b 00
0x009ba3cd
= 102.000 Nm
Lower angle limit
20 a1 07 00
0x0007a120
= 50.00
°
End angle
a4 ba 14 00
0x0014baa4
= 135.85
°
Upper angle limit
a0 25 26 00
0x002625a0
= 250.00
°
Error code
00 00
0
Error class
00
0
1
The display in BS350 under
System test
CS field bus data
(see Figures
) does not include the control signals.
Table 6–55:
Meaning of the results in the output area of the data buffer for a single-channel tightening process
Name
Results output
Meaning of the output result
Example
The following is assumed:
•
3-step tightening program (2,A / 3,A / 4,A)
•
Result of 2nd tightening step (3,A):
NOK
, with corresponding QC
•
Programmed end step:
Loosen if NOK
Result:
OK
If the results of the end step are selected as the result of the complete tightening process (option
Tightening results from end step
), the result of the complete tightening process is
OK
. The quality
code for the complete tightening process provides the quality codes configured for
OK
.
Summary of Contents for Rexroth Tightening System 350
Page 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Page 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...