308
Bosch Rexroth AG
| Tightening Technology
3 608 878 300
System 350
| 3 608 878 300/2019-03
6.4.5.3
Results output via a compact system
Fig. 6–58:
Chronological sequence for processing and transferring the tightening results via field bus for a tightening process in the
compact system
Here, the actual tightening end of the tightening process is also indicated by the evaluation signals (Ok,
Nok) switching from L to H. At this point, the tightening spindle can be removed from the processed
component.
After results processing, the data buffer with the results values is transferred to the field bus module. The
field bus master can collect the results data from the data buffer after the process end signal CyCmp is
set. This process is initiated by the master.
(A)
Single-channel tightening
(B)
Data buffer result (field bus)
Ch x.y Cw
Start
Ch x.y InCy
Sequence active
Ch x.y CyCmp
Process end
Ch x.y Ok
Process OK
Ch x.y ResRs
Result reset
(1)
Cycle
(2)
Invalid
(3)
Valid