3 608 878 300
Tightening Technology |
Bosch Rexroth AG 323
System 350
| 3 608 878 300/2019-03
6.5.3.2
Results output in a single-channel tightening
Fig. 6–67:
Chronological sequence for processing and transferring tightening results for a single-channel tightening via the printer
protocol
Due to the hardware buffering in the data interfaces, parts of the printer protocol may be output only after
process end (CH x.y CyCmp). For complete data transfer, you must wait for the protocol end ("ETX" end
trigger character 0x03).
Here, the actual tightening end is also indicated by the evaluation signals (CH x.y Ok, CH x.y Nok)
switching from L to H. At this point, the tightening spindle can be removed from the processed
component.
The transfer is started once the results have been processed. After the results have been transferred
successfully, the tightening cycle is ended (control signal CH x.y CyCmp).
6.5.3.3
Data quantity for tightening results files
Data volume and expected transfer time for tightening results files
(A)
Single-channel tightening
(B)
Output on printer
Ch x.y Cw
Start
Ch x.y InCy
Start active
Ch x.y CyCmp
Process end
Ch x.y Ok
Evaluation
(1)
Cycle
(2)
Sequence
(3)
Result processing
(4)
See explanation below
In version 2.1 and below, the results output is not necessarily completed after a process end for single-
channel tightening.
Summary of Contents for Rexroth Tightening System 350
Page 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Page 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...