Settings in the BS350
In the B350 operating system, click
System
Tightening cell data
XML
.
Information on the individual parameters can be found in section
Make the settings shown in the figure below.
If the "Buffer tightening results locally" checkbox is activated:
If the connection to the ToolsNet gateway is lost, tightening results are buffered on the CF350
memory module.
If the "Buffer tightening results locally" checkbox is not activated:
If the connection to the ToolsNet gateway is lost, tightening results will also be lost.
Fig. 6–69:
Settings in the BS350
If the "Buffer tightening results locally" checkbox is activated, the Tightening System 350 requires the
CF350 memory module (Compact Flash card) for local data storage, see section
Ethernet tightening data output“
.