348
Bosch Rexroth AG
| Tightening Technology
3 608 878 300
System 350
| 3 608 878 300/2019-03
6.7.7.5
Tightening program messages
MID 0010
Request to upload tightening program/tightening application numbers
MID 0011
Response to upload of tightening program/tightening application numbers
Sent by:
superordinate computer
Request of all existing tightening program or tightening application numbers
Note:
-
Revision:
001
(supported by Rexroth OP and Rexroth OP-Ford and Rexroth OP-BMW)
Data field:
is empty, 0 bytes
Possible response
MID
Error no. Comment
Response to upload of tightening
program/tightening application numbers
0011
–
All valid tightening program or tightening application
numbers in the tightening controller are transferred
after this command is output.
Sent by:
Tightening controller
Transfer of all existing tightening program or tightening application numbers of the tightening controller.
Note:
Supported OP variants and systems:
– Rexroth OP
– CS351 compact system: Only program numbers 0 … 99 that are available are output.
– Modular system 350: Only application numbers 0 … 47 or 99 that are actually available are output.
– Rexroth OP-Ford
– CS351 compact system and tightening channels (spindle 01 ...): Only program numbers 0 … 99 that are
available are output.
– KE350 (spindle 00): Only application numbers 0 … 47 that are available are output.
– Rexroth OP BMW
– CS351 compact system and tightening channels (spindle 01 ...): Only program numbers 0 … 99 that are
available are output.
– KE350 (spindle 00): Only application numbers 0 … 47 that are available are output.
Revision:
(supported by Rexroth OP and Rexroth OP-Ford and Rexroth OP-BMW)
Data field:
Total data length = (1 + number of tightening programs/tightening application) x 3 bytes
Possible response:
none
Table 6–81:
MID 0011 revision 001
Parameter
Comments
Bytes
Tightening program/tightening
application number
The value consists of three ASCII characters.
ID
-
Value range
000 – 999
Presetting
-
Example:
Number of tightening
programs
/tightening
applications
1
Value
001
3
Tightening program/tightening
application number
The value consists of three ASCII characters.
ID
-
Value range
000 – 999
Presetting
-
Example:
Tightening program
/tightening
application
number
2
Value
002
3
Data length revision 001 (with one tightening program/tightening application)
6
Summary of Contents for Rexroth Tightening System 350
Page 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Page 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...