3 608 878 300
Tightening Technology |
Bosch Rexroth AG 375
System 350
| 3 608 878 300/2019-03
MID 0061 revision 002
Date/time of the last change
Date and time of the last change in the tightening program settings.
The value consists of 19 ASCII characters in the format
YYYY-MM-DD:HH:MM:SS.
ID
21
2
Value range
0 – 9, "-" and ":"
Presetting
-
Example:
Date/time of the
change
1/12/2009:2:43:57 PM
Value
1/12/2009:2:43:57 PM
19
OK/NOK counter status
Status of the OK/NOK counter.
– 0: if not 1 or 2
– 1: Ch x.y CntOK = 1
– 2: OK counter not used (not configured)
Rexorth OP/Rexroth OP-BMW: Exception if
MID61/MID65 evaluation
and batch information from application result
is selected in the
configuration for Open Protocol: In application operation, the OK/NOK
counter of the application is applied (parameterized from the job).
The value consists of one ASCII character.
ID
22
2
Value range
0 – 2
Presetting
-
Example:
OK counter
status
OK counter not used
Value
2
1
Tightening ID
With an activated OP, consecutive number for each tightening result (for
further information, see
).
The value consists of ten ASCII characters.
ID
23
2
Value range
0000000000 – 9999999999
Presetting
-
Example:
Tightening ID
123456
Value
0000123456
10
Data length revision 001
211
Table 6–99:
MID 0061 revision 002
Parameter
Comments
Bytes
Cell ID
This is where the 7th level of the location name is returned.
The value consists of four ASCII characters.
ID
01
2
Value range
0000 – 9999
Presetting
-
Example:
Cell ID
21
Value
0021
4
Table 6–98:
MID 0061 revision 001
Parameter
Comments
Bytes
Summary of Contents for Rexroth Tightening System 350
Page 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Page 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...