426
Bosch Rexroth AG
| Tightening Technology
3 608 878 300
System 350
| 3 608 878 300/2019-03
MID 0523
Cancel socket change
MID 0524
Select socket tray
MID 0524 revision 001
Sent by:
superordinate computer
The subscription to the change in sockets (Logon socket change,
) is reset.
Note: -
Revision:
001 (supported by Rexroth OP and Rexroth OP-BMW)
Data field:
is empty, 0 bytes
Possible response
MID
Error no. Comment
Command accepted
0005
–
Command error
0004
91
Activation for socket change not available
Sent by:
superordinate computer
By means of this message, the individual LEDs at the socket tray for the worker guidance can be set or reset.
Note:
In the PLC assignment table, the signals for the LEDs of the socket tray (BoxNut LED…) must be stored on
the OP PLC module.
(supported by Rexroth OP and Rexroth OP-BMW)
Data field:
Parameter IDs and parameter values, 24 bytes
Possible response
MID
Error no. Comment
Command accepted
0005
–
Command error
0004
65
Socket tray not configured
Table 6–120:
MID 0524 revision 001
Parameter
Comments
Bytes
Tray 1
Defines the status of socket-LED 1.
ID
01
2
Value range
– 0 (deactivated)
– 1 (activated)
Presetting
-
Example:
Tray 1
deactivated
Value
0
1
Tray 2
Defines the status of socket-LED 2.
ID
02
2
Value range
– 0 (deactivated)
– 1 (activated)
Presetting
-
Example:
Tray 2
Activated
Value
1
1
Tray 3
Defines the status of socket-LED 3.
ID
03
2
Value range
– 0 (deactivated)
– 1 (activated)
Presetting
-
Example:
Tray 3
Activated
Value
1
1
Summary of Contents for Rexroth Tightening System 350
Page 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Page 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...