430
Bosch Rexroth AG
| Tightening Technology
3 608 878 300
System 350
| 3 608 878 300/2019-03
MID 0571 revision 001
MID 0573
Select job number
MID 0573 revision 001
Possible response
MID
Error no. Comment
Command accepted
0005
–
Command error
0004
98
Request timeout in the control or PLC signal not
assigned in the PLC assignment table.
Table 6–123:
MID 0571 revision 001
Parameter
Comments
Bytes
Job start status
Defines the status of the job start
The value consists of three ASCII characters.
ID
01
2
Value range
– 0 (deactivated)
– 1 (activated)
Presetting
-
Example
Tightening
channel number
1
Value
1
1
Data length revision 001
3
Sent by:
superordinate computer
This command can be used to select the job number of the tightening channel.
Note:
In the PLC assignment table, the
Job <n>
signal must be applied to the OP module (OP 5.0 - OP 5.7).
(supported by Rexroth OP and Rexroth OP-BMW)
Data field:
3 bytes
Possible response
MID
Error no. Comment
Command accepted
0005
–
Command error
0004
98
Request timeout in the control or PLC signal not
assigned in the PLC assignment table.
Table 6–124:
MID 0573 revision 001
Parameter
Comments
Bytes
Job number
Number of the job.
The value consists of three ASCII characters.
ID
-
Value range
000 – 999
Presetting
-
Example
Job number
001
Value
001
3
Data length revision 001
3
Summary of Contents for Rexroth Tightening System 350
Page 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Page 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...