446
Bosch Rexroth AG
| Tightening Technology
3 608 878 300
System 350
| 3 608 878 300/2019-03
6.9.1
Settings in the BS350 operating system
The following settings for the VW-XML Protocol are available in BS350 under
System
Tightening cell
data
VW-XML 2.x
.
Table 6–135:
Settings in BS350 for VW-XML 2.x
Field
Element
Description
Protocol
Activated
The data protocol is active if this option is selected.
Version
Data protocol selection:
– VW-XML 2.0
– VW-XML 2.1
(subsequently referred to as
VW-XML
)
Interface
TCP/IP port A (control data) Selection of the desired TCP/IP port for data exchange with the
tightening controller. (Default setting: 4700)
TCP/IP port B (process
data)
Selection of the desired TCP/IP port for data exchange with the
tightening controller.
(Default setting: 4710)
Keep alive timeout (A)
Indication of the time in which a message from the master PC is to be
received. If no message is received within this time at the port, the
connection will be disconnected.
(Default setting: 8 seconds)
Keep alive timeout (B)
Indication of the time in which the tightening controller must send a
message to the master PC. If no message is received within this time
at the port of the master PC, it will disconnect the connection. (Default
setting: 6 seconds)
Archive server operation
If this option is activated, communication set-up via the TCP/IP port A
is not necessary. Via TCP/IP port B, the tightening system sends
tightening results automatically to the master PC.
TCP/IP address B
(Input field only available if the
Archive server operation
option is
activated)
The TCP/IP address of the master PC, to which the tightening results
are sent.
ACK Timeout
Indication of the time in which a confirmation (acknowledge) is to be
received. If no confirmation is received within this time at the port, the
connection will be disconnected.
(Default setting: 3 seconds)
Local buffering of the
tightening results
(Input field only available if the
Archive server operation
option is
activated)
This setting has no effect. The tightening system always stores the
tightening results in the CF350 mass storage memory if the
connection to the master PC is interrupted.
Delay in transmission
repetition from local buffer
(Input field only available if the
Archive server operation
option is
activated)
This setting has no effect.
Delay in the clearance of
buffered files
(Input field only available if the
Archive server operation
option is
activated)
This setting has no effect.
Summary of Contents for Rexroth Tightening System 350
Page 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Page 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...